Retry a reconciliation job
Re-drives one reconciliation job that is stuck or has failed. A FAILED or REQUIRES_MANUAL_REVIEW job gets a new job of the same type in PENDING, linked by sourceJobId, and the original job stays unchanged. A FINALIZING job returns to IN_PROGRESS, and any other non-terminal job returns to PENDING, once it has gone without an update for longer than the deadline of its status. A Flow A sync-verification job in IN_PROGRESS is refused with 409 (PIX-0155) until it fails. A file reconciliation that still waits for its file requests a new one, which uses a CID-file request. A PENDING or COMPLETED job is refused with 409 (PIX-0155), and so is a job whose status differs from expectedStatus. The 409 does not name the current status: read it with List reconciliation jobs. Send an X-Idempotency key and a reason: every call is recorded in an audit log. The vsync-admin permission comes only from the DICT Hub permission declaration, which is off until you turn it on in BYOC.
Cabeçalhos
REQUIRED. Client-supplied replay key, at most 64 bytes. A request without it is refused with PIX-0030 @ 400 before the handler runs. Replaying the same key with a divergent request is PIX-0031 @ 412 -- at the edge for one hour, and permanently thereafter from the administrative audit record.
"a1b2c3d4-0000-0000-0000-000000000001"
Parâmetros de caminho
Corpo
Resposta
The retry was applied, or an identical X-Idempotency replay returned the outcome of the first request. sourceJobId is present only when the retry created a new job from a terminal one.