Initiate connectivity (ECO) test
Prerequisite: an active certificate (see rotateCertificate, activateCertificate) and a READY readiness report (see getReadiness) before the connectivity test; a passing connectivity test is itself the prerequisite for a submit operation (see createBankTransferOperation). Builds a GEN0001 echo request addressed to the given participant, persists it as SUBMITTED before rail dispatch, and lets the outbound relay dispatch it to the RSFN. The counterparty answers with GEN0001R1 echoing the message back; the response correlates by NUOp and confirms the test. Idempotent — replaying the same X-Idempotency key with the same parsed request (member order and whitespace do not count; any other difference, such as number spelling, null for an absent field, or an unknown member, is another request) returns the cached response.
Cabeçalhos
Corpo
Send the GEN0001 with SFN header C04 = 1: the frame is signed by a certificate BACEN has not activated yet (Manual de Segurança do SFN v6.00, items 5.6.2 and 5.6.3), so the echo can be tested before the GEN0006 activation. Default false sends the normal C04 = 0 frame.
false
Optional free-text MsgECO payload echoed back by the counterparty. At most 50 characters (BACEN type MsgECO, Catálogo v5.13 Vol IV: Alfanumérico 0..50; the Vol III GEN0001 sample reads "texto de ate 50 posicoes"). Anything longer is refused by the wire facet before BACEN ever sees it.
50"connectivity check"
Resposta
Created